- B SERIES INTRANET SEARCH AND SETTINGS HOW TO
- B SERIES INTRANET SEARCH AND SETTINGS SERIAL
- B SERIES INTRANET SEARCH AND SETTINGS DRIVERS
- B SERIES INTRANET SEARCH AND SETTINGS DRIVER
Step 19) Next, confirm you would like to download your program into the Micro you selected: Step 18) At this point if you made any changes to your program you may be prompted to save it:
![B series intranet search and settings B series intranet search and settings](https://image.slidesharecdn.com/intranet-hnl-121217103909-phpapp01/95/intranet-case-studies-hnl-sps-31-638.jpg)
Alternatively, you could go online by selecting the Online button: Step 17) To download your program just select the Download button. Step 16) Then in the popup Communications window expand your Ethernet driver and select your Micro: Step 15) Next, from the Comms menu select System Comms: Step 14) Now open either RSLogix Micro or RSLogix 500, and then open your program file:
B SERIES INTRANET SEARCH AND SETTINGS DRIVER
Step 13) Now double click on your new driver in the RSWho window and after a few seconds you should see your Micro appear: Step 12) Here, add the Ethernet address of your MicroLogix (see notes above Step 1 for that procedure) and then click on OK: Step 11) As before, select the driver, click Add New, and then click Ok: Step 10) If after ten seconds of browsing RSLinx does not find your MicroLogix, you may wish to try adding it manually by adding the Ethernet Devices driver under Communications, Configure Drivers, Available Driver Types: Step 9) Next, double click on your new driver in the RSWho window as shown below:
B SERIES INTRANET SEARCH AND SETTINGS DRIVERS
Step 8) And click on Close to close the Configure Drivers window: Step 7) Now click on OK to close the driver window: Beware not to choose WiFi or Bluetooth network cards if your MicroLogix is not connected to them: Step 6) Now select the Ethernet Port on your PC to which your MicroLogix is connected. Step 5) And accept the default name by clicking on OK: Step 3) Now from the Available Driver Types drop down list select the Ethernet/IP driver, a driver which will attempt to automatically find your MicroLogix on Ethernet: Step 2) Next launch RSLinx Classic, and then under the Communications menu select Configure Drivers: Ping 192.168.1.10) as explained in this article.
![B series intranet search and settings B series intranet search and settings](https://bloximages.chicago2.vip.townnews.com/kokomotribune.com/content/tncms/assets/v3/editorial/1/eb/1eb28678-5f5f-11e8-8a01-4b89399660c9/5b06ccbed6577.image.jpg)
![B series intranet search and settings B series intranet search and settings](https://i.ytimg.com/vi/6MdLD2cnPGg/maxresdefault.jpg)
Note: If you have a newer PC your Ethernet port will likely support “Auto MDI-X,” in which case you can also use a standard Ethernet patch cable. You can also connect directly using an Ethernet crossover cable.
B SERIES INTRANET SEARCH AND SETTINGS HOW TO
While many with Ethernet experience will know how to accomplish the above, for those less experienced I'll add some additional info below: The easiest way to obtain this is to connect them both to the same physical network and logical network. The first step is to insure you have Ethernet connectivity between your PC and MicroLogix PLC. And for images of the MicroLogix 1100 communications ports see this article.
B SERIES INTRANET SEARCH AND SETTINGS SERIAL
If you'd prefer to setup communications using serial RS232 DF1, see this article. You'll also want to make sure you know the Ethernet address of your MicroLogix 1100 which you can find by following this article. Notes and prerequisites: Before you begin, insure you have the correct software. So you need to know how to setup RSLinx Classic to communicate to an Allen-Bradley MicroLogix 1100 using Ethernet in order to download or go online with RSLogix? Well you're in luck as in today's article I'll walk you step by step through how to setup RSLinx communications, as well as how to download or go online from RSLogix: